BIOPAC® Systems, Inc. Logo

Biopac Student Lab Biomed Engineering Systems

The Gold Standard for Life Science Instruction

Complete biomechanical engineering teaching solution

The preferred application for better science and greater discovery

BSL Biomedical Engineering - Win
Part #: BSLBME-W, BSLBME-M

BSL System with MP36 and hardware for 13 guided lessons plus 16 dynamic lessons and student-designed BME experiments. The BSL Biomedical Engineering System provides extensive recording and analysis options for signal processing curriculum, including bioelectric and biomechanical studies. The data acquisition unit includes four universal, software-programmable amplifiers that can record biopotential and transducer signals. The BSL hardware/software combination creates a virtual instrument that can be tailored for a wide range of measurements with analysis tools for digital filtering, integration, differentiation, FFT, convolution, correlation, and a host of signal processing options. The Breadboard allows students to build and test real circuits and then use the software to compare real results to simulation. Collect, display and investigate data with the BSL System, or use it to direct data to industry-standard applications like MatLab or LabVIEW.

Increase Student Engagement

Students record data from their own bodies, animals, or tissue preparations. +29 experiments.

Fast, Easy Set-Up & Operation

Reduces setup time by 90%. Guided lessons w/ on-screen instructions, video demos & sample data.

Empowers Better Teaching

Extensive out-of-class resources. New Curriculum Management System. 3 Systems to meet a range of needs.

BSL Biomedical Engineering Teaching System - Win
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Systems - Education
Subcategories: Biomedical Engineering - Education

Alternatives
For the same Platform

Details

Compatibility


The BSL Biomedical Engineering system comes with the following:

  • BSL 4 Software (Lessons and PRO)
  • BSL Laboratory Manual MANBSL4
  • Searchable PDF Manuals and Tutorials (BSL PRO, Instructor’s Guide, Answer Key, etc.)
  • MP36 Data Acquisition Unit with USB Cable, DC Adapter (110V/60Hz or 220V/50Hz) & Cord (Hospital Grade)
  • 2 x Electrode Lead Sets – SS2LB
  • Disposable Electrodes (100/pk) – EL503
  • Abrasive Pads (10/pk) – ELPAD
  • Hand Dynamometer – SS25LB
  • BP Cuff Transducer – SS19LB
  • Electronic Stethoscope Transducer – SS30L
  • Air Flow Transducer, factory-calibrated – SS11LB
  • Disposable Filtered Mouthpieces (10/pk) – AFT36
  • Disposable Noseclips (10/pk) – AFT3
  • Hand Switch – SS10L
  • Headphones – OUT1A
  • Pulse Transducer – SS4LA
  • Signal Processing Breadboard Kit – SS39L
  • Breadboard Accessories – BSL-BMEACC
  • SS2L to breadboard interface – TCI22
  • Electronic Breadboard Probe – SS60L

Perform 29 or more lessons with this core package:

Muscular

  • BSL1 Standard & Integrated EMG
  • BSL2 Motor Unit Recruitment & Fatigue
  • H07 EMG Contractions—Active Learning
  • H27 Facial EMG
  • H34 EGG Electrogastrogram
  • H36 Muscular Biofeedback
  • BSL5 Components of the ECG (Lead II)
  • BSL6 Leads I, II, III & Einthoven’s Law
  • BSL7 ECG & Pulse
  • BSL16 Blood Pressure & Korotkoff Sounds
  • BSL17 Heart Sounds & Cardiac Events
  • H08 Dive Reflex—Active Learning
  • H23 Signal Averaged ECG
  • H32 Heart Rate Variability

Pulmonary Function

  • BSL12 Pulmonary Function: Vol. & Capacities
  • BSL13 Pulmonary Flow Rates: FEV and MVV

Neurophysiology

  • BSL3 EEG Relaxation & Brain Rhythms
  • BSL4 Alpha Rhythms in the Occipital Lobe
  • BSL10 EOG Eye Movement, Saccades & Fixation
  • BSL11 Reaction Time
  • H10 EEG & Hemispheric Asymmetry
  • H12 EOG Saccades & Displacement
  • H13 EOG Visual Tracking vs. Imagination
  • H14 Ocular Fixation while reading
  • H15 Ocular Fixation while viewing an image
  • H16 Reflexes & Reaction Time – Active Learning

Bioengineering

  • H02 Compartmental Modeling
  • H20 BME Filtering
  • H25 BME Signal Processing (8 modules)
  • H26 ECG R-wave Detector
  • H33 FFT Fast Fourier Transformation

Learn more about the Biomedical Engineering system.

Videos

Biopac Student Lab Teaching Systems

BSL Systems | BME Biomedical Engineering

Biopac Student Lab Student Download

Support

Downloads/Resources

Knowledge Base

Manual

Upgrade

Recommended Items

Spotlight On
b-alert x10

B-Alert Wireless EEG with AcqKnowledge plus Cognitive State Software

Simple, portable, accurate, wireless This complete system provides acquisition and analysis of high fidelity wireless EEG plus ECG with the B-Alert X10 headset and sensor strips (1 small, 1 medium), plus AcqKnowledge software with powerful analysis tools, including automated scoring and reporting options, and B-Alert Cognitive State analysis software. The B-Alert X10 mobile-wireless EEG system delivers real-time measurements for a […]

View All
Latest News

BIOPAC Ranked #1 for Physiology Experiments by HAPS Members

The Human Anatomy & Physiology Society (HAPS) found that BIOPAC’s Student Lab System (BSL) and AcqKnowledge software were the number one ranked data acquisition and analysis systems for physiology experiments performed in introductory A&P labs. According to HAPS surveys conducted in 2013 and 2016, BIOPAC products are used and preferred by members in more labs than […]

Integrating Eye Tracking Data with Neuromarketing Parameters

Hardware and software packages from BIOPAC allow commercial consumer marketing teams to easily combine precise eye tracking data with physiological data recording. Here are a few notable studies recording physiology with eye tracking data: Predicting Advertising Success: While neurophysiological methods have become increasingly popular to better understand marketing phenomena among academics and practitioners, the success of […]

Read All
Request a Demonstration
Request a Demonstration