Airflow Transducer
Part #: SS11LB, SS11LA

The SS11LB handheld airflow transducer is intended for human use and can be used to perform a variety of tests relating to airflow and lung volume. The transducer is factory-calibrated to measure airflows within -10 to +10 L/second within ±5%. The transducer has a removable head (RX117A) for sterilization and replacement.

  • No calibration syringe is required.
  • Airflow measurement is much less susceptible to changes in transducer orientation.
  • New tiered airflow head design allows for direct connection to multiple standard pulmonary ID/OD hoses and components without the need for couplers.
  • Flow correction that was previously only included in lessons (via syringe) is now in Lessons and BSL PRO analog preset.

Use standard disposable mouthpieces with disposable bacterial filters, or use an autoclavable mouthpiece, depending on your budget and/or lab preference. Direct connection to AFT36 35 mm Filtered mouthpiece. The SS11LB can also be used with the AFT22 Non-Rebreathing T-valve for low dead space requirements, and to monitor expiration and inspiration signals separately.

If using an Airflow Transducer with the GASYSS3 Gas Analysis System, SS11LB is required (SS11LA is not compatible with GASSYS3).

SS11LB is compatible with BSL 4.1.1 and above or AcqKnowledge 4.4.2 and above.

Older model SS11LA with RX117 is available for systems running BSL 4.1.0 and below or AcqKnowledge 4.4.1 and below (software upgrade recommended), and is the shipping airflow transducer model for Chinese and Russian BSL 3.7 Systems. Use AFT1 Filter + AFT2 mouthpiece with SS11LA flow head RX117.

See More...

BIOPAC Physiology Teaching Tools
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Gas Analysis - Education, Transducers - Research
Subcategories: Airflow Transducers - Education, Airflow - Research

Alternatives
For the same Platform

Details

Compatibility


For the most accurate measurements, transducer should be warmed up for two minutes prior to use (no airflow required).

The detachable flow head (RX117A or RX117) is dishwasher safe.

Recommended sterilization: cold sterilization (i.e., Cidex) or autoclave.

Users may still perform their own calibrations using the optional FLOWCAL kit and downloadable template.  The user calibration values are stored with the transducer, so the user calibration is applied on any computer to which the transducer is connected.  The factory calibration may also be automatically restored by the user.

BSL 4.1.1 software is required to use the SS11LB.  Earlier software versions will not recognize the transducer or apply the factory calibration.

Medium Airflow Head Connections

The SS11LB, TSD117A, and TSD117A-MRI transducers use flow head RX117A, which has multiple outer diameters to directly connect to the AFT36 filter/mouthpiece, AFT7L tubing, and other pulmonary products.

AFT Series Part # RX117A Flow Head Coupler/Combination/Notes
AFT1 Direct connection to RX117A, but not recommended due to airflow restriction;  use AFT36 in place of AFT1 + AFT2.
AFT6A Not recommended for RX117A. Use FLOWCAL calibration kit. May still be connected to the RX117A using the AFT11A coupler included with the AFT6A.
AFT7L Direct connection to RX117A.
AFT8 Autoclavable Mouthpiece Either connect directly if sterilizing airflow head. If not sterilizing head can use AFT4 disposable filter (connect AFT8 to smaller diameter of filter, larger diameter to RX117A).
AFT9 Reusable Mouthpiece 35 mm – replaced by AFT8 Autoclavable Mouthpiece; the AFT8 has a better fit with the RX117A.
AFT10 Disposable Facemask AFT11H 35 mm OD/28.6 mm ID.
AFT12 Direct connection to RX117A. Snug, but fits in the inner diameter of airflow head.
AFT13 (OBSOLETE) AFT13 has been discontinued. Replaced by the AFT36 filter/mouthpiece.
AFT23 Low-cost T-Valve Reusable mouthpiece: AFT4 + AFT8 + AFT11D 35 mm OD/35 mm OD

Disposable mouthpiece:  AFT36 + AFT11D 35 mm OD/35 mm OD

AFT26 2 L syringe AFT11D 35 mm OD/35 mm OD. This coupler is included in the FLOWCAL calibration kit.
AFT36 Disposable Filter with Integrated Mouthpiece Direct connection to RX117A.

 

Support

Downloads/Resources

Knowledge Base

Recommended Items

Spotlight On
free BIOPAC webinar

Bioimpedance and Cardiac Output with TREV—a User-friendly, Noninvasive Technique

Learn a technique—Trans-radial Electrical Bioimpedance Velocimetry (TREV)—that is more user-friendly and less invasive than the transthoracic method. TREV measures blood movement in the radial and ulnar arteries of the forearm via bioimpedance.
Topics Covered:
– Presentation and discussion of TREV
– Derived Indices Relevant to TREV
– Hardware setup
– Participant setup
– Recognizing good quality and bad quality data
– Demonstration with the grip anticipation test
– Review of results from other tests

Watch On Demand

Register Now
Latest News

New Citations | BIOPAC in Exercise Physiology

Exercise physiology is the study of the body’s response to physical activity. Research in exercise physiology allows for insights in health and for a better understanding of the functions of the body at work. Here are some recent studies in exercise physiology that utilized BIOPAC tools for their research… Effect of exercise on electrocardiographic parameters […]

Electrocardiography Guide Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration