Gas Analysis – Exercise

Use the new gas analysis system to create a powerful metabolic analyzer (cart) for students to measure expired O2 and CO2 and with lessons for VO2, Respiratory Exchange Ratio, and Basal or Resting Metabolic Rate. Combine metabolic and cardiac output measurements to give students a detailed view of a variety of cardiopulmonary responses.

Hardware

Name Description Cart
Disposable Bacterial Filters Disposable bacteriological filters for use with 22 mm breathing circuits, such as BIOPAC pneumotach transducers SS11LA, TSD117, or SS11. These filters remove airborne bacteria. Pore size—VFE: 3.1 micron; BFE: 2.8 micron MRI Use: MR Safe (see Specifications for components)

$48.00 - $745.00Select options

Disposable Mouthpiece These mouthpieces connect to the TSD117 pneumotach transducer and other 22 mm breathing circuits. Connects directly to the AFT1 bacterial filter, AFT22 non-rebreathing T valve (via AFT11C) and the TSD117 air flow transducer. (Pkg. 10 or 250) MRI Use: MR Safe (see Specifications for components)

$17.00 - $182.00Select options

Disposable Noseclip These nose clips gently squeeze the nostrils shut to prevent errors when using mouth-breathing circuits. Available in packs of 10 or 250. MRI Use: MR Safe (see Specifications for components)

$19.00 - $242.00Select options

Disposable Long-term Electrodes These disposable, long-term recording, snap electrodes provide the same signal transmission as reusable electrodes, with added convenience and hygiene. Each peel-and-stick electrode is pre-gelled and designed for one use only. Standard snap connection Ag/AgCl contact (11 mm dia) Electrolyte: hydrogel (4% chloride salt) Size: 41 mm vinyl backing Moderate adhesive Qty: 50 Use disposable snap…

$50.00 - $400.00Select options

General-purpose Electrodes These pre-gelled disposable electrodes have a circular contact and are most suitable for short-term recordings, including surface EMG, ECG, EOG, etc. The small vinyl backing allows close electrode placement where necessary, and a slightly less firm adhesive allows "ouchless" removal. The electrodes incorporate liquid electrolyte gel and moderately-high chloride salt concentration for quick, accurate readings.…

$45.00 - $340.00Select options

Bioimpedance Strip Electrodes This disposable strip electrode is used for bioimpedance applications. Each carbon film strip electrode uses isotonic hydrogel to adhere to the participant and provide a conductive medium. The electrodes have a fabric backing for added comfort and conformity to the subject. The electrode uses a snap fit stud for easy interfacing with BIOPAC electrode leads. Advantages of…

$24.00 - $400.00Read more

Cal. Syringe, 600 ml Medium pump syringe used for injecting a precise volume of air (600 ml) through airflow assemblies for precise calibration. The AFT6A fits (ridged) 27 mm OD, 30 mm OD, and 15 mm ID. Fits directly to AFT13 (30 mm) filter and mouthpiece AFT23 (27 mm) non-rebreathing T-valve with replacement valves Use coupler AFT11A to connect…

$198.00Add to cart

Face Mask, Adult, w/T-valve This adult facemask with integral non-rebreathing T-valve is a high performance, very low dead space, low airflow resistance mask and valve; suitable for high airflow applications (e.g., exercise physiology). The AFT25 incorporates two gas sampling ports (female Luer) for interfacing with the AFT20 Gas Sampling Kit. Each AFT25 includes one mask. See also: Optional AFT25 Masks…

$737.00 - $825.00Select options

Cal. Syringe, 3 liter The AFT27 3.0 Liter Calibration Syringe is certified to have a volume that meets or exceeds an accuracy of 0.5% of the total displacement volume (3 liters ±0.5%). This adjustable aluminum calibration syringe is shipped with the volume locked to 3.0 L and BIOPAC templates and software settings are set for 3 L.  The locking collar and…

$429.00Add to cart

Heated Airflow Pneumotach 1.565 L/sec The SS50L heated pneumotach can perform a variety of pulmonary measurements relating to lung volume, airflow, and expired gas analysis. Each pneumotach transducer consists of an airflow pneumotach head coupled to a precision, highly sensitive, differential pressure transducer (RX137F1 to SS40L) and is equipped with an internal heating element and 6-volt power supply AC137A. The pneumotachs…

$1,964.00Add to cart

Pneumotach transducer (spirometer) ±2.66 L/sec Airflow The SS51L pneumotach can perform a variety of pulmonary measurements relating to airflow, lung volume, and expired gas analysis. Each pneumotach transducer consists of a heated airflow pneumotach head coupled to a precision, highly sensitive, differential pressure transducer (RX137G1 to SS40L). The SS51L pneumotach is equipped with an internal heating element and includes the AC137A 6-volt power supply. The…

Login for pricingAdd to cart

Lead set, shielded, BSL This fully-shielded cable assembly permits high resolution recording of biopotentials using our EL500 series disposable electrodes. The 2 meter adapter is terminated with standard pinch connectors to interface with EL500 series snap electrodes. The SS2LB interfaces with Biopac Student Lab data acquisition units (MP3X or MP45) and the MP36R research unit. Compatible releases BSL Lessons…

$245.00Add to cart

Noninvasive Cardiac Output Sensor – MP3X The SS31LA simultaneously measures Impedance Magnitude (Zo; labeled “Z” on the module) and Derivative of Impedance Magnitude (dZ/dt; labeled “DZ” on the module). The SS31LA noninvasively records the parameters associated with Cardiac Output measurements. Measure changes in Cardiac Output under a variety of conditions: laying down, sitting up, standing up, and post-exercise. Use the Kubicek…

Request PriceAdd to cart

WHAT'S NEW

New Citations | BIOPAC and BCI

Applying brain-computer interfaces and robotics to research opens doors to lots of new...

Join the BIOPAC Community

Stay Current

Stay Connected

Request a Demonstration
Request a Demonstration