Cardiovascular Hemodynamics – Pharm.

Lessons cover ECG (1- through 12-lead), cardiac output, and continuous blood pressure. A heart sounds lesson allows students to listen to and record heart sounds, while comparing them to the ECG complex. The frog heart lesson explores cardiac rate and contractile response under a regimen of drug doses. Students can analyze blood pressure signals automatically, online and also manually, off-line. The system can record Monophasic Action Potentials and spontaneous nerve activity.

Hardware

Name Description Cart
General-purpose Electrodes These pre-gelled disposable electrodes have a circular contact and are most suitable for short-term recordings, including surface EMG, ECG, EOG, etc. The small vinyl backing allows close electrode placement where necessary, and a slightly less firm adhesive allows "ouchless" removal. The electrodes incorporate liquid electrolyte gel and moderately-high chloride salt concentration for quick, accurate readings.…

$45.00 - $340.00Select options

High Impedance Cables Micro-electrode interface cables for MP36/36R, MP35, MP30, or MP45* These fully-shielded, unity gain, high-impedance, differential input, electrode interface cables permit high resolution recording of biopotential signals. These interface cables incorporates dual ultra-high impedance buffer amplifiers (one for Vin+ and one for Vin-) to allow for connections to needle electrodes, wire electrodes, or very small surface electrodes…

$242.00Select options

Multi-lead ECG Cable (MP3X) The SS29L Multi-Lead ECG Cable permits high resolution electrodcardiogram recordings. The lead set will allow you to simultaneously record Leads I, II, III, aVR, aVL, aVF, plus one precordial chest lead. A 12-Lead ECG recording can be obtained by alternating the chest lead electrode from position V1 through V6. The cable is terminated in three…

$490.00Add to cart

Lead set, shielded, BSL This fully-shielded cable assembly permits high resolution recording of biopotentials using our EL500 series disposable electrodes. The 2 meter adapter is terminated with standard pinch connectors to interface with EL500 series snap electrodes. The SS2LB interfaces with Biopac Student Lab data acquisition units (MP3X or MP45) and the MP36R research unit. Compatible releases BSL Lessons…

$245.00Add to cart

Pressure Transducer – MP3X/45 The SS13L is used to measure direct arterial or venous blood pressure in animals, or to record the pressure changes within an in-vitro circuit such as a Langendorff heart preparation. Connect to tubing via the standard rotating Luer Lok tube fittings. The cable terminates in a connector interface for an MP3X or MP45 unit. The transducer comes…

$435.00Add to cart

Stethoscope for BSL The BSL Stethoscope was developed to teach students the standard procedure for listening to heart sounds and Korotkoff sounds with a normal stethoscope and at the same time record sound data. A microphone in the stethoscope simultaneously records the sound the student is hearing, and the BSL software will display the soundwave during and after…

$259.00Add to cart