Cardiovascular Hemodynamics – Animal

Isolate components of the ECG and use the averaging features in the software to automate ECG analysis. Use the electronic stethoscope to examine heart sounds and then overlap the data to correlate the sounds with the mechanical events of the cardiac cycle. Record arterial blood pressure and record systolic, diastolic, mean, dP/dt max and min, and use the noninvasive cardiac output sensor to record stroke volume and cardiac output. If flow signals are available, record them simultaneously with pressure to examine vascular resistance and compliance. Plot pressure versus flow to obtain P/V Loops.

Hardware

Name Description Cart
General-purpose Electrodes These pre-gelled disposable electrodes have a circular contact and are most suitable for short-term recordings, including surface EMG, ECG, EOG, etc. The small vinyl backing allows close electrode placement where necessary, and a slightly less firm adhesive allows "ouchless" removal. The electrodes incorporate liquid electrolyte gel and moderately-high chloride salt concentration for quick, accurate readings.…

$40.00 - $295.00 Select options

Bioimpedance Strip Electrodes Use as an alternative to band electrodes This unique disposable strip electrode is designed for bioimpedance applications. The electrode is silver laminated on porous, medical-grade cloth, with industry-standard medical grade adhesive, medium tackiness. The silver-silver chloride (Ag/AgCl) electrode provides accurate and clear transmission of surface biopotentials and is latex free. Advantages of the Strip Electrode…

Read more

High Impedance Cables Micro-electrode interface cables for MP36/36R, MP35, MP30, or MP45* These fully-shielded, unity gain, high-impedance, differential input, electrode interface cables permit high resolution recording of biopotential signals. These interface cables incorporates dual ultra-high impedance buffer amplifiers (one for Vin+ and one for Vin-) to allow for connections to needle electrodes, wire electrodes, or very small surface electrodes…

$210.00 Select options

Lead set, shielded, BSL This fully-shielded cable assembly permits high resolution recording of biopotentials using our EL500 series disposable electrodes. The 2 meter adapter is terminated with standard pinch connectors to interface with EL500 series snap electrodes. The SS2LB interfaces with Biopac Student Lab data acquisition units (MP3X or MP45) and the MP36R research unit. Compatible releases BSL Lessons…

$190.00 Add to cart

Pressure Transducer - MP3X/45 The SS13L is used to measure direct arterial or venous blood pressure in animals, or to record the pressure changes within an in-vitro circuit such as a Langendorff heart preparation. Connect to tubing via the standard rotating Luer Lok tube fittings. The cable terminates in a connector interface for an MP3X or MP45 unit. The transducer comes…

$315.00 Add to cart

Stethoscope, BSL The SS30L was developed to teach students the standard procedure for listening to heart sounds and Korotkoff sounds with a normal stethoscope and at the same time record sound data. A microphone in the stethoscope simultaneously records the sound the student is hearing, and the BSL software will display the soundwave during and after recording.…

$265.00 Add to cart

Noninvasive Cardiac Output Sensor - MP3X The SS31LA simultaneously measures Impedance Magnitude (Zo; labeled “Z” on the module) and Derivative of Impedance Magnitude (dZ/dt; labeled “DZ” on the module). The SS31LA noninvasively records the parameters associated with Cardiac Output measurements. Measure changes in Cardiac Output under a variety of conditions: laying down, sitting up, standing up, and post-exercise. Use the Kubicek…

Request Price Add to cart

Spotlight On
Ventilator Validation Kit

Ventilator Validation and Test Equipment

The Ventilator Validation Kit supports new prototype development, existing design validation for production testing, mobile field testing and verification, and other uses where accurate pressure and flow measurements are critical. The Ventilator Validation Kit provides ventilator manufacturers and prototype developers with a complete solution for validating new medical/hospital-grade ventilator products intended for human use. The VVK100-SYS includes […]

View All
Latest News

BIOPAC Now Offers Practical Lab Instruction for Remote Students to Learn Physiology during the Coronavirus Pandemic

Distance Learning Solutions for a Hands-on Lab Experience GOLETA, California (May 21, 2020) – BIOPAC Systems announced a new solution for university level educators seeking solutions for practical lab learning in an independent setting due to stay-at-home restrictions and social distancing rules. The premier life science education system, Biopac Student Lab, has been expanded with […]

New Citations | A Physiological Perspective to Stress Management and Mental Health

Musical Intervention as Stress Regulation There is no question that music can be beneficial in regulating mood and psychological states, but what type of musical intervention assists the greatest in stress reduction? Researchers turn to physiological signals to compare the stress reduction effects of two types of musical interventions: music listening and musical improvisation. Stressor […]

Read All
Request a Demonstration
Request a Demonstration