Nerve Conduction Studies

AcqKnowledge nerve conduction data

Stimulate and record signals from nerves in-vivo or in-vitro; using the built-in software averaging mode, it’s possible to record signals from in-vivo nerves using skin surface electrodes only. Surface electrodes can also be used for peripheral nerve stimulation (PNS) and to evaluate the effects of stimulation to motor nerve endings in terms of electrical or mechanical response. Configure stimulation sources to provide electrical, somatosensory or visual stimulation, and vary the duration and level of stimulus. In addition to the stimulator, up to 16 amplifiers can be simultaneously employed to record nerve and/or muscle responses. The system software permits easy determination of peak times and maximum responses for a variety of nerve conduction studies (NCS) and nerve conduction velocity tests (NCV).

Use the AcqKnowledge® stacked plot mode to overlap both the stimulus waveform and the response. The software allows you to advance through each of the responses and the software highlights the response and specific stimulus waveform to make it easier to determine which response relates to each stimulus waveform.

Details

This is one of many ADVANCED FEATURES for the selected Application. Scroll down for hardware options.

Support

Application Notes

Knowledge Base

Spotlight On
BIOPAC Facial EMG

FEMG Smart Amplifier

The fEMG Electromyography Smart Amplifier is designed specifically for recording facial EMG signals and electrical activity from other small muscle groups. Use with AcqKnowledge™ software to analyze facial expressions and startle paradigms. BIOPAC’s new Smart Amplifiers are designed for great data. Smart Amplifiers improve performance by amplifying the physiological signal close to the subject, which allows a high-level […]

View All
Latest News

New Citations | Do We Really Trust Autonomous Vehicles?

A System to Measure Physiological Response During Social Interaction in VR Children with Autism Spectrum Disorder (ASD) have a difficult experience in responding to social cues and actions. This pilot study measured the effectiveness of Virtual Reality in creating a social environment for children, measured with a BIOPAC MP Series data acquisition system and Worldviz […]

Electrocardiography Guide Now Available

BIOPAC’s just released Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines […]

Read All
Request a Demonstration
Request a Demonstration