Cardiac Output can be noninvasively determined by employing electrical bioimpedance measurement techniques. Electrical bioimpedance is simply the characteristic impedance of a volume of tissue and fluid. In the case of…
Search
The BIOPAC Hardware API gives software developers control over BIOPAC acquisition units. A Hardware API is available for MP160, MP150 & MP36R (Research Systems) or MP36 & MP35 (Education Systems, 4-channel units); not available…
Showing 4 of 146 products
BSL Systems have been cited in thousands of Scientific Papers. Selected citations are provided below—for a complete list, search Google Scholar for Biopac Student Lab software and related hardware: MP36,…
This application note reports the performance of BIOPAC hand dynamometers SS25LA and TSD121C at grip forces below 1 kg. These devices are specified to register clench force range 0-50 kgf.…
The NIBP100D noninvasive blood pressure system provides a continuous, beat-to-beat, blood pressure signal recorded from the fingers of a subject. The system outputs a continuous blood pressure waveform that is…
This application note is for Mac users running OS High Sierra (10.13), OS Mojave (10.14), or higher who are performing a first-time installation of MP36R, MP36, or MP35 hardware drivers…
AcqKnowledge and Biopac Student Lab both have mechanisms for acquiring and transmitting digital information. Psychology Software Tools, the authors of E-Prime®, refer to such signals as “digital triggers.” This application…
BIOPAC lets you measure physiology anywhere with innovative, compatible solutions that can be used by anyone for meaningful discovery. We make high-quality scientific tools for physiology measurement and interpretation with…
Related Hardware Compatible with MP160 Smart Amplifiers NICO100D Cardiac Output, EBI100D Electrical Bioimpedance Amplifiers NICO100C Cardiac Output, EBI100C Electrical Bioimpedance MRI NICO100C-MRI Cardiac Output Amplifier Wireless BN-NICO Cardiac Output Amplifier & BN-NICO-T Transmitter Compatible with MP36 and MP36R (4-channel…
Do it your way…customize and automate your own routines with BIOPAC Developer tools. BIOPAC Developer tools give you customization and greater access to your data to help you expedite and…
BIOPAC Data Acquisition Unit Drivers BIOPAC Certified Drivers can be downloaded directly from the Microsoft website. Please click a hardware model below and read the directions before downloading the driver…
BIOPAC user Dr. Jason Braithwaite, a Cognitive Psychologist and Brain Science lecturer at England’s University of Birmingham, used a 4-channel data acquisition unit with analysis software, EDA/SCR electrodes, and body temp transducers to scientifically evaluate…
To determine if your installed BIOPAC software has an update available, check OS Compatibility & Release History. Registered users may be eligible for a free update to current release software. Contact BIOPAC support to check…
Biopac Student Lab (BSL) integrated hardware, software, and curriculum systems allow students to record data from their own bodies, animal, or tissue preps to learn principles of life science physiology.…
This BNC adapter is designed to output signals from the built-in low voltage stimulator in MP36A and MP36 units through the “Analog Out” port. The female BNC supports easy connection…
For BSL 3.7.2 or BSL 3.7.3 under Windows XP or Vista This utility will allow users to easily switch between multiple Biopac Student Lab hardware options (MP36, MP35, or MP30)…
Biopac Student Lab sofware included with BSL Teaching Systems and BSL System Upgrades has been updated to BSL 4.0.2. New since the BSL 4.0.1 release… BSL Lessons for Blood Pressure and Heart Sounds…
While the Biopac Student Lab is known as the “Gold Standard” in life science education, the hardware can also be used to perform physiology research. We have gathered a few…
BSL 4.1.6 Supports the following data acquisition hardware MP36 or MP35 4-channel systems MP46 or MP45 2-channel systems MP41 “BSL Home” 1-channel system Multi-media Lessons Full-color onscreen guides Embedded…
The BSL Hardware Guide describes how to connect and set up various signal electrodes, transducers, and other devices for use with the BSL system using an MP36, MP35, MP30,…
To learn how the Biopac Student Lab PRO works, use this interactive tutorial with the Mac demo or PC demo and read the Overview Chapter of the BSL PRO Software…
Biopac Student Lab update! BSL 3.7.7 Lessons & PRO BSL Lessons & PRO with updated teaching tools–now installed as one application–(for MP3X English/Windows systems) Click for Upgrade to BSL 3.7…
If you have any installed version of Biopac Student Lab 3.6, please purchase a software upgrade or a full system upgrade to enjoy the powerful new features of the MP36 and BSL 4.
If you have any installed version of BSL 3.7.0, you are eligible for a FREE UPGRADE to BSL 3.7.3. Contact BIOPAC to confirm registration and obtain a download for a reduced version…
Installed Version/Support Info Upgrade Options and Procedure BSL 3.7.3 with a build date of 06.25.2008. Your software is current if the Help > About Biopac Student Lab dialog shows Build…
The Chronos® USB-based response and stimulus device features millisecond accuracy in the areas of stimulus, response, sound output, and external device communication—this level of timing accuracy cannot be achieved using…
Discontinued items—Click the item for Specs & Setup Contact BIOPAC to discuss other options. AC100A power supply – use AC300A Accelerometers 5 G: SS26LA now SS26LB, TSD109C now TSD109C2, SS26B…
Certified BIOPAC Device Drivers DRIVER GUIDES BSL 4 or above: BSL 4 Driver Troubleshooting GuideBSL 3.7.7: BSL Driver Troubleshooting Guide BSL 3.7.6 or below (except MP45): BSL Driver Guide BSL…
BIOPAC offers a variety of setups for recording electrodermal activity, including Reusable: skin conductance transducer (MP150+TSD203 or MP36+SS3LA) and electrodermal gel (GEL101). Disposable: MP150+EDA100C amp with 2 x LEAD110A or MP36+SS57LA EDA…
EDA Questions and Answers Your colleagues submitted these questions during BIOPAC EDA Webinars. Topics include EDA Skin Prep/Gel Application EDA Electrode Placement & Grounding EDA Recording Systems EDA Data Measurement & Analysis EDA Artifact…
Biopac Student Lab—“The Gold Standard” pour l’enseignement des sciences de la vie Pour les enseignants qui ont besoin d’une solution rapide et facile à mettre en œuvre, qui souhaitent accroître…
The “Electrode Check” port on the front panel of MP36 and MP35 units is dseigned to measure impedance. As a rule of thumb, impedance levels below 10 kOhms are ideal,…
The terminology for electrical connections to human subjects is not universally agreed upon. “Ground” and “reference” are often used interchangeably. This is not a good practice as there are different…
This BSL PRO lesson describes hardware and software setup of the BSL PRO System to record and measure nerve conduction velocity along the ulnar nerve of a human subject. Stimulation can…
This PRO Lesson describes basic reflex exercises and details hardware and software setup of the BSL Lessons System to record the reflex reaction. All data collection and analysis is done…
This BSL PRO Lesson describes how to record an electrogastrogram (electrical activity from the stomach muscles) from a resting human subject. software: Biopac Student Lab PRO 3.7.7, 3.7.5 or 3.7.3 (template was created…
Acknowledgements to Dr. David Sherman, UCSB This BSL PRO Lesson examines the impact of social support on stress. Students will use the BSL System to record and measure electrodermal activity…
Use the hardware application program interface (BHAPI) to create your own programs to control BIOPAC's MP36/35 or MP150 hardware.
3.5 mm phone plug cable with a built-in attenuation. Provides a divide by 10 attenuation to scale the ±10 V signal range of BIOPAC’s 100 series modules to the ±2 V…
MP Systems can interface with most of the major visual presentation packages by using the STP100C module. The STP100C module provides an optically isolated connection between the computer that is…
It is possible to use LabView® with the either the MP150, MP36* or MP35 hardware. The BIOPAC Hardware API gives software developers control over the BIOPAC acquisition unit – MP150…
If the Biopac Student Lab Startup Wizard window does not list lessons in the “Choose a Lesson” window, and if the software did NOT generate an error message indicating that it could…
MP36/35 to E-Prime, Direct RT, MediaLab, Inquisit, and other systems that connect via the parallel port. This item replaces the STP35A.
Study EEG under a variety of conditions to explore relaxation and brain rhythms, software will filter and display each rhythm separately: alpha, beta, delta, and theta. Select from a variety…
Study EEG under a variety of conditions to explore relaxation and brain rhythmssoftware will filter and display each rhythm separately: alpha, beta, delta, and theta. Select from a variety of…
BIOPAC provides software and hardware that allows research teams to record and analyze numerous body signals for physiological experimentation. Here are a few notable studies using BIOPAC equipment that cover Respiration, EEG, and…
HRV, EMG, and EEG studies using BIOPAC hardware and software include: DON’T STRESS Humans encounter various stressful situations everyday at work, home, and school. Such stress when experienced at high degrees and/or for…
BIOPAC provides software and hardware that allows research teams to study large group interactions. Here are a few notable studies using BIOPAC equipment for large group research focusing on participation and EDA data.…
Recent studies in Psychophysiology, EMG, ECG and PPG measurement utilizing BIOPAC software and hardware: Fight or Flight (Reflex Response Time) “Fight or flight” is a physiological response that occurs due to a…
BIOPAC provides software and hardware that allows engineers to study the body. Here are a few notable studies using BIOPAC equipment for Biomedical Engineering research. Rehabilitating the Rehab Industry Could physical therapy…