Tissue resistance is mathematically described as the real part of the tissue impedance and tissue reactance is defined as the imaginary part of the tissue impedance. To determine these parameters, measure the impedance magnitude and phase using the EBI100C. Use the AcqKnowledge Equation Generator to multiply the magnitude by the cosine of the phase to obtain the tissue resistance and by the sine of the phase to obtain the tissue reactance. Invert the resistance value to obtain tissue conductance.
Hardware Bundles are complete solutions for the specified application. Choose your preferred platform and bundle, then click "Request Pricing" to request an estimate, add/remove items, or complete purchase. If you have questions about specific items, click through to the product web page for details and specifications, or contact your Local Sales contact.
MP36R System
Wired | Tissue Resistance and Reactance Measurement
MP36R with AcqKnowledge plus NICO sensor, lead set, disposable strip electrodes, & disposable general purpose electrodes
MP160 System
Wired | Tissue Resistance and Reactance Measurement
MP160 System with NICO and ECG amplifiers and disposable electrodes
MP160 System
Wired | Tissue Resistance and Reactance Measurement
MP160 with AcqKnowledge plus ECG & Electrical Bioimpedance Amps with disposable electrodes
MP36R System
MP160 System
MP160 System
MP160 System
Wireless | Tissue Resistance and Reactance Measurement
MP160 with AcqKnowledge plus BioNomadix wireless NICO & ECG with disposable electrodes
MP160 System
MP160 System
MRI | Tissue Resistance and Reactance Measurement
MP160 System with NICO amplifier and disposable electrodes for MRI
MP160 System
MP36R System
Animal | Tissue Resistance and Reactance Measurement
MP36R with AcqKnowledge plus NICO sensor, reusable 8 mm snap electrodes, & electrode lead adapter
MP160 System
Animal | Tissue Resistance and Reactance Measurement
MP160 System with NICO and ECG amplifiers, needle electrodes & impedance checker
MP36R System
MP160 System
High-performance mobile fNIR Imaging Systems are stand-alone functional brain imaging solutions for continuous NIR spectroscopy (NIRS). These top of the line systems provide cognitive function assessment and eliminate a great many of the drawbacks of a functional MRI. Mobile subjects are comfortable and can respond naturally in real-world situations to take a test or perform mobile […]
View AllBIOPAC provides software and hardware that allows research teams to run autonomic function tests while collecting physiological data. Here are a few studies focusing on BIOPAC’s ability to record physiological signals during autonomic function testing. The Internet, Sleep, and Heart Rate Does internet usage lead to poorer sleep? Using a BIOPAC Data Acquisition System to measure cardiovascular […]
BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]
Read All