Login for data acquisition systems, amplifiers, transducers, electrodes and accessories data acquisition systems, amplifiers, transducers, electrodes and accessories transducers for life science data acquisition gas analysis systems stimulators and stiumulus presentation electrodes, leads, and accessories More Main Categories of Products Noninvasive blood pressure amplifiers, temperature amplifier, and interface modules

Overview of data acquisition and analysis systems for research

Biopac Student Lab overview

New! Biopac Science Lab for secondary education

Product releases

Announcements & Product Updates

Events
 
Education  Amplifiers  Temperature  

FIBER OPTIC TEMPERATURE SYSTEM - FOTS100

For Estimate or Purchase
Request Information
Fiber Optic Temperature System

Stand-alone Fiber Optic Temperature System

FOTS100 includes control unit with RS-232 port, ± 5 V analog output, and rubber boot; power via 9 V battery or wall power.

This is a stand alone system, but it can also be interfaced to BIOPAC MP Systems:

MP150 or MP100 System: add CBL101 (separate purchase).

MP36/35 System: add SS70L isolated BNC interface and a BNC-to-RCA cable (separate purchase)

The analog output parameters comprise the scale factor and the offset. The scale factor corresponds to the physical unit per Volt (unit/V) output by the system, while the offset corresponds to the physical value at which the user wants the analog output to be at zero volt. For example, with a scale factor set to 10 °C / V and the offset set to 5 °C, the temperature as a function of the analog output voltage is given by:

Temperature = [Voltage output] x 10 °C / V + 5 °C

The default value of the scale factor is 50 °C / V (or its equivalent in °F) and the default value of the offset is 0 °C (or its equivalent in °F).

During a No Signal condition, constant values are output as follows: analog output value = 0 Volt,  RS-232  serial ports = 65 536.0.

For more details, please see the complete FOTS100 User Manual, available under the Resource tab below.

Use with high-accuracy, MRI-compatible fiber optic temperature probes (separate purchase):

TSD180 Rectal Temp Probe: 300 µm OD Polyimide tubing, 8 m

  • The Polyimide round tubing protects the sensing element its flexibility and rigidity provide excellent pushability.

TSD181 Surface Temp Probe: sensor 1 mm OD, PFA tubing 0.9 mm OD, 8 m

  • cable sheath rated up to 85 °C.

The glass tube at the end of the probe provides a robust protection over the sensing element as well as a firm connection from sensor to cable.
 

Note: FOTS100, TSD180, and TSD181 are suitable for MR field strength of 3T and lower; contact BIOPAC to discuss options for 7T and higher.




You might also be interested in the following items:
Item Description View Cart
TSD181FO Temp Surface Probe, 8 m For Estimate or Purchase
TSD180FO Rectal Temp Probe, 8 m For Estimate or Purchase