BIOPAC data acquisition and analysis for education
Biopac Student Lab systems for life science lab experiments Physiology teaching labs - data acquisition and analysis systems for the life sciences
Login for data acquisition systems, amplifiers, transducers, electrodes and accessories data acquisition systems, amplifiers, transducers, electrodes and accessories transducers for life science data acquisition gas analysis systems stimulators and stiumulus presentation electrodes, leads, and accessories More Main Categories of Products data acquisition and analysis systems for life science education

Overview of data acquisition and analysis systems for research

Biopac Student Lab overview

New! Biopac Science Lab for secondary education

Product releases

Announcements & Product Updates

Events
 
Education  Systems  Biomedical Engineering  

BSL BIOMEDICAL ENGINEERING - MAC - BSLBME-M

For Estimate or Purchase
Request Information
BSL Biomedical Engineering - Mac
The BSL Biomedical Engineering Teaching System provides extensive recording and analysis options for signal processing curriculum, including bioelectric and biomechanical studies. The data acquisition unit includes four universal, software-programmable amplifiers that can record biopotential and transducer signals. The BSL hardware/software combination creates a virtual instrument that can be tailored for a wide range of measurements with analysis tools for digital filtering, integration, differentiation, FFT, convolution, correlation, and a host of signal processing options. The Breadboard allows students to build and test real circuits and then use the software to compare real results to simulation. Collect, display and investigate data with the BSL System, or use it to direct data to industry-standard applications like MatLab or LabVIEW.
 
Learn more about the Biomedical Engineering system.
 
The BSL Biomedical Engineering system comes with the following:
  • BSL Lessons Software
  • Biopac Student Lab PRO Software
  • BSL Laboratory Manual MANBSL3S
  • BSL PRO Manual (Searchable PDF file)
  • MP36/35 Data Acquisition Unit with USB Cable, DC Adapter (110V/60Hz or 220V/50Hz) & Cord (US or Euro)
  • 2 x Electrode Lead Sets - SS2L
  • Disposable Electrodes (100/pk) - EL503
  • Abrasive Pads (10/pk) - ELPAD
  • Hand Dynamometer - SS25LA
  • BP Cuff Transducer - SS19L
  • Electronic Stethoscope Transducer - SS30L
  • Air Flow Transducer - SS11LA
  • Calibration Syringe - AFT6A
  • Disposable Bacterial Filters (10/pk) - AFT1
  • Disposable Mouthpieces (10/pk) - AFT2
  • Disposable Noseclips (10/pk) - AFT3
  • Hand Switch - SS10L
  • Headphones - OUT1
  • Pulse Transducer - SS4LA
  • Signal Processing Breadboard - SS39L

Perform 29 or more lessons with this core package:

Muscular
  • BSL1 Standard & Integrated EMG
  • BSL2 Motor Unit Recruitment & Fatigue
  • H07 EMG Contractions—Active Learning
  • H27 Facial EMG
  • H34 EGG Electrogastrogram
  • H36 Muscular Biofeedback
Cardiovascular
  • BSL5 Components of the ECG (Lead II)
  • BSL6 Leads I, II, III & Einthoven’s Law
  • BSL7 ECG & Pulse
  • BSL16 Blood Pressure & Korotkoff Sounds
  • BSL17 Heart Sounds & Cardiac Events
  • H08 Dive Reflex—Active Learning
  • H23 Signal Averaged ECG
  • H32 Heart Rate Variability
Pulmonary Function
  • BSL12 Pulmonary Function: Vol. & Capacities
  • BSL13 Pulmonary Flow Rates: FEV and MVV
Neurophysiology
  • BSL3 EEG Relaxation & Brain Rhythms
  • BSL4 Alpha Rhythms in the Occipital Lobe
  • BSL10 EOG Eye Movement, Saccades & Fixation
  • BSL11 Reaction Time
  • H10 EEG & Hemispheric Asymmetry
  • H12 EOG Saccades & Displacement
  • H13 EOG Visual Tracking vs. Imagination
  • H14 Ocular Fixation while reading
  • H15 Ocular Fixation while viewing an image
  • H16 Reflexes & Reaction Time - Active Learning
Bioengineering
  • H02 Compartmental Modeling
  • H20 BME Filtering
  • H25 BME Signal Processing (8 modules)
  • H26 ECG R-wave Detector
  • H33 FFT Fast Fourier Transformation

Apple Mac software Biopac Student Lab Biomedical EngineeringSoftware runs on Mac OS X; click for Compatibility Table.



Topics
- Join the BIOPAC Forum. Share info and insights with other users.
AC mode
Amplifier filter settings
BSL error: unable to access a folder for saving data
BSL file save location
BSL PRO optimize range
Compatibility: OS & Computer Requirements
Customize BSL Lessons
DC mode
Duplicating waveforms
Electrode Check on MP3X units
Graph template files
High pass filters
IIR vs. FIR filters
Impedance levels
Interfacing with 3rd party software
LabView interface
Low pass filters
MP3X Filters
Notch filter
Offline (ensemble) averaging
Opening BSL PRO files in the Analysis (RSD) software
Optimal ground placement
Respiration transducer TSD201/SS5LB/SS5B
Saving acquisition settings
Signal drifts to zero
SS2L or SS1LA for EDA/GSR measurements
Tachogram - R-R intervals
Tutorial on Electrostatic Discharge
Typical impedance cardiography values
Unipolar EEG
Upgrading from PCMCIA to USB
USB Drivers
Using BIOPAC research amplifiers with the BSL System
Specifications Recommended Items Knowledge Base Resources
Click here to find more information on Research Click here for more information on Education
 
 
Click here to find more information on Research Click here for more information on Education