BIOPAC data acquisition and analysis for education
Biopac Student Lab systems for life science lab experiments Physiology teaching labs - data acquisition and analysis systems for the life sciences
Login for data acquisition systems, amplifiers, transducers, electrodes and accessories data acquisition systems, amplifiers, transducers, electrodes and accessories transducers for life science data acquisition gas analysis systems stimulators and stiumulus presentation electrodes, leads, and accessories More Main Categories of Products data acquisition and analysis systems for life science education

Overview of data acquisition and analysis systems for research

Biopac Student Lab overview

New! Biopac Science Lab for secondary education

Product releases

Announcements & Product Updates

Events
 
Education  Systems  Biology  

BIOLOGY TEACHING SYSTEM - WIN - BSLBIO-W

For Estimate or Purchase
Request Information
Biology Teaching System - Win

The Biopac Student Lab Biology Teaching System can record signals from cells, organs, insects, animals and human subjects to facilitate a spectrum of application opportunities. The system has new options for pH, dissolved oxygen and calorimetry (connections & software features). A wide range of lessons covers the cardiovascular, immune, respiratory, pulmonary, metabolic, digestive and nervous systems. User-friendly recording options and analysis tools promote student inquiry and active learning. Employ new software options to develop new lessons specifically tailored to unique course material.

Learn more about the Biology education system.

The Biology system includes:

Basic BSL System BSLBSC - click for Compatibility Table
Airflow Filters (10/pk) AFT1
Airflow Mouthpieces (10/pk) AFT2
Airflow Nose Clips (10/pk) AFT3
Airflow Transducer SS11LA
BP Cuff Transducer SS19L
Calibration Syringe (600 ml) AFT6A
Colored Paper (for BSL9) PAPER1
Dissolved O2 Probe Interface BSL-TCI16
EDA (GSR) Lead SS57L
EDA (Isotonic) Electrodes (100/pk) EL507
Electrode Gel GEL1
Electronic Stethoscope Transducer SS30L
Force Transducer SS12LA
Hand Dynamometer SS25LA
Hand Switch SS10L
Headphones OUT1
High-impedance Cable BSLCBL9
Multi-Lead ECG Cable SS29L
Needle Electrodes x 3 EL452
Nerve Chamber NERVE2
pH Probe Interface BSL-TCI21
Pressure Transducer SS13L
Pulse Transducer SS4LA,
Recording Nerve Cable BSLCBL4B
Respiratory Effort Transducer SS5LB
Stimulator BSLSTM
Stim. Electrode for humans HSTM01
Stim. Electrode for animals ELSTM2
Stimulator Nerve Cable BSLCBL2A
Surgical Tape TAPE1
Temperature Transducer SS6L

Perform 50 or more lessons with this core package:

Muscular

A02 Frog Gastrocnemius
A05 Visceral Smooth Muscle
A11 Resting Potential from Crawdad Manual
A12 Membrane Potential (muscle)
A15 Earthworm Smooth Muscle
BSL1 Standard & Integrated EMG
BSL2 Motor Unit Recruitment & Fatigue
H06 Finger Twitch
H07 EMG Contractions - Active Learning
H27 Facial EMG
H34 EGG Electrogastrogram
H36 Muscular Biofeedback

Cardiovascular

A04 Frog Heart
BSL5 Components of the ECG (Lead II)
BSL6 Leads I, II, III & Einthoven’s Law
BSL7 ECG & Pulse
BSL16 Blood Pressure & Korotkoff Sounds
BSL17 Heart Sounds & Cardiac Events
H01 12-lead ECG
H04 BP Response to Straining
H05 WAnT Wingate Test
H08 Dive Reflex - Active Learning
H23 Signal Averaged ECG
H32 Heart Rate Variability

Pulmonary Function

A07 Dissolved O2 (goldfish)with your probe
BSL8 Respiratory Cycle
BSL12 Pulmonary Function: Vol. & Capacities
BSL13 Pulmonary Flow Rates: FEV and MVV
BSL15 Aerobic Exercise Physiology

Neurophysiology

A01 Frog Pith & Prep
A03 Frog Nerve
A06 Cockroach Nerve
A08 Action Potential-Earthworm
A09 Turtle Heart
A14 CPG Hornworm
BSL3 EEG Relaxation & Brain Rhythms
BSL4 Alpha Rhythms in the Occipital Lobe
BSL9 GSR and Polygraph
BSL10 EOG Eye Movement, Saccades & Fixation
BSL11 Reaction Time
BSL14 Biofeedback: Relaxation & Arousal
H03 Nerve Conduction (ulnar nerve)
H10 EEG & Hemispheric Asymmetry
H11 Mirror TestEDA Sensory motor learning
H12 EOG Saccades & Displacement
H13 EOG Visual Tracking vs. Imagination
H14 Ocular Fixation while reading
H15 Ocular Fixation while viewing an image
H16 Reflexes & Reaction Time - Active Learning
H24 Habituation

Biomedical Engineering

H02 Compartmental modeling
H20 Filtering
H33 FFT Fast Fourier


Topics
- Join the BIOPAC Forum. Share info and insights with other users.
AC mode
Amplifier filter settings
BSL error: unable to access a folder for saving data
BSL file save location
BSL PRO optimize range
Compatibility: OS & Computer Requirements
Customize BSL Lessons
DC mode
Duplicating waveforms
Electrode Check on MP3X units
Graph template files
High pass filters
IIR vs. FIR filters
Impedance levels
Interfacing with 3rd party software
LabView interface
Low pass filters
MP3X Filters
Notch filter
Offline (ensemble) averaging
Opening BSL PRO files in the Analysis (RSD) software
Optimal ground placement
Respiration transducer TSD201/SS5LB/SS5B
Saving acquisition settings
Shelf life for Sodium Sulfite
Signal drifts to zero
SS2L or SS1LA for EDA/GSR measurements
Tachogram - R-R intervals
Tutorial on Electrostatic Discharge
Typical impedance cardiography values
Unipolar EEG
Upgrading from PCMCIA to USB
USB Drivers
Using BIOPAC research amplifiers with the BSL System
Specifications Recommended Items Knowledge Base Resources
Click here to find more information on Research Click here for more information on Education
 
 
Click here to find more information on Research Click here for more information on Education